Page 28 of 51 Changing parameters on distance measuring sensors
This filter method simulates an arithmetic mean value calculation over several measurements. The setting
for filter strength takes affect on the attenuation.
The applied method is not exactly a true mean value calculation from the mathematical point of
view; due to the limited RAM storage capacity of a microcontroller a similar method is employed.The
maximum allowable attenuation should experimentally be derived.
F03
In the case of arrival of different distance values the sensor-near measured values are preferred.
F04
In the case of arrival of different distance values the sensor-far measured values are preferred.